Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber With ComfortSeal Medium Mask

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber With ComfortSeal Medium Mask

Brand/Manufacturer: MONAGHAN MEDICAL
Hpfy Stores Save
  • HyGiene Products
  • Non Returnable
  • FSA Approved

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber helps improve the delivery of medications from Metered-Dose Inhaler (MDI) canisters. It reduces the coordination required between canister activation and inhalation, making it easier for the patient to use the MDI correctly. It also reduces drug deposition to the mouth and throat, helping to eliminate unpleasant taste of medication or hoarseness.

Why choose Monaghan AeroChamber Plus Z STAT?

  • Cost-Effective Aerochamber
  • AeroDynamic Chamber Design
  • Universal MDI Adapter
  • One-way valve
  • Delivers 22% more of the medication than the original AeroChamber
  • Made in USA
  • FSA Approved

Item # Desc Pkg Price
78710Z AeroChamber Plus Z STAT With Medium Mask Each
$32.89
$22.99
78710Z AeroChamber Plus Z STAT With Medium Mask 5/Pack
$163.29
$114.29

AeroChamber Plus Z STAT Chamber Features

  • Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber with ComfortSeal Mask is clear chamber for easy visualization of proper activation of the MDI
  • It provides effective delivery of medication to the lungs
  • Aerodynamic chamber design with an innovative valve system that separates and filters out coarse aerosol particles
  • It is ideal for patients with asthma
  • One-way valve to hold and protect aerosol until inhalation begins
  • Delivers 22% more medication than the original AeroChamber
  • Universal MDI adapter allows use with most MDIs
  • Durable holding chamber made of a unique, flexible, shatterproof plastic
  • Z STAT custom anti-static polymer chamber minimizes static charge which maximizes performance

Parts of Monaghan AeroChamber Valved Holding Chamber

 

Exhalation Valve: Easy flow Exhalation Valve minimizes re-breathing and directs exhaled flow away from the face of the patient

Anti-Static Chamber: Increases aerosol suspension time to assist dose assurance of metered dose inhaler medication

Inhalation Valve: Low resistance Inhalation Valve makes it easier for patients with shallow or low volume breathing patterns to inhale the medication

Backpiece: Universal backpiece fits all commonly prescribed Metered Dose Inhalers

ComfortSeal Mask: It is made of soft, flexible silicone and fits snuggly to patient face to ensure a close, comfortable fit that promotes proper drug delivery

 

What are the Benefits of Monaghan AeroChamber Plus Z STAT?

Aerochamber With Mask Aerodynamic Valve and Baffle Design:

  • One-way valve ensures only the right-sized particles exit the chamber through inhalation
  • Low resistance and easily opens to allow patient to inhale without difficulty
  • Allows to inhale smaller medication particles for fast and targeted delivery to the lungs
  • Prevents patient from exhaling into the chamber, leaving any remaining medication in the chamber available for the next breath of patient

Z STAT Aerochamber Anti-Static Chamber:

  • Anti-Static Chamber of Monaghan Z Stat minimizes static charge, increasing aerosol suspension time within the chamber and making more medication available, unlike the static-prone chambers, where static-charged aerosol particles used to attach to the chamber walls
  • Clear polymer chamber allows to see the medication enter the chamber from the MDI inhaler

AeroChamber Plus Z STAT Comfort Seal Mask:

  • Fits snugly and comfortably on the face
  • Makes it easier for children to take their treatments
  • Less technique dependent than a mouthpiece
  • Secure seal ensures maximized drug delivery and reduced leakage

AeroChamber Plus Exhalation valve:

  • Low resistance valve for easy and unrestrained breathing
  • Directs the exhaled medication away from face and eyes
  • Latex free and made of soft, flexible silicone

AeroChamber Z STAT is User Friendly:

  • Suitable for smaller children
  • BPA and Latex free
  • Attractive design
  • Easy-to-read instructions
  • Simple to use and maintain
  • Dishwasher-safe components

 

How AeroChamber Plus Z STAT works?

AeroChamber Z Stat aVHC maximizes medication delivery to lungs by separating the small medication particles from large particles. As the patient inhales, the smaller particles float out of the one-way valve of chamber into the respiratory tract where they easily reach those areas of the lungs that need it the most. The Z Stat chamber holds any of the remaining small particles that are not inhaled the first time, which allows the patient to take more than one breath per puff of medicine administered. It is especially helpful for children or others who cannot achieve a high peak expiratory flow (PEF), and assures that the maximum amount of prescribed medicine reaches the lungs for optimum benefit. This model comes with a built-in ComfortSeal mask that makes it easier for children to take their treatments.

When to use AeroChamber Plus Z STAT Chamber?

  • AeroChamber Z Stat aVHC is intended to be used by patients who are under the care or treatment of a physician or licensed healthcare professional
  • This device is to be used by these patients to administer aerosolized medication from Metered Dose Inhalers
  • The intended environments for its use include home, hospitals and clinics

Monaghan Plus Z STAT Anti-Static Valved Holding Chamber Illustration Using With And Without aVHC:

Monaghan AeroChamber Plus Z STAT Anti-Static Valved Holding Chamber With ComfortSeal Mask
 

 

What to buy with AeroChamber+ Z STAT

 

 

How to use Monaghan AeroChamber Plus With Mask?

How to use Monaghan AeroChamber Plus Z STAT 1. Carefully examine the product for damage, missing parts or foreign objects. Any foreign objects should be removed. The product should be replaced immediately if there are any damaged or missing parts. If necessary, use the inhaler (MDI) alone until a replacement is obtained. If your symptoms worsen, please seek immediate medical attention.
How to use Monaghan AeroChamber Plus Z STAT 2. Before use, make sure that instructions supplied with MDI have been read. Remove cap(s).
How to use Monaghan AeroChamber Plus Z STAT 3. Shake the MDI well immediately before each use. Insert the MDI into the back piece of the chamber.
How to use Monaghan AeroChamber Plus Z STAT 4. Apply mask to face and ensure there is an effective mask/face seal. While maintaining an effective mask/face seal the patient should exhale through the mask.
How to use Monaghan AeroChamber Plus Z STAT 5. Depress MDI at beginning of slow deep inhalation. Hold breath as long as possible, up to 10 seconds before breathing out. If patient has difficulty with slow deep breaths, an alternative is to keep face tight on mask and breathe slowly 2-3 times after depressing MDI. Administer one puff at a time.
How to use Monaghan AeroChamber Plus Z STAT 6. Slow down inhalation if you hear the Flow Signal Whistle sound.
How to use Monaghan AeroChamber Plus Z STAT 7. Follow instructions supplied with the MDI on amount of time to wait before repeating steps 3–6 as prescribed.

How to clean Monaghan Aerochamber Plus Z STAT?

 How to clean Monaghan Aerochamber With Mask 1. Remove back piece only. Do not remove mask or tamper with valves during cleaning.
 How to clean Monaghan Aerochamber With Mask 2. Soak both parts for 15 minutes in lukewarm water with liquid detergent. Agitate gently.
 How to clean Monaghan Aerochamber With Mask 3. Rinse in clean water.
 How to clean Monaghan Aerochamber With Mask 4. Shake out excess water. Do not rub dry.
 How to clean Monaghan Aerochamber With Mask 5. Let air dry in vertical position.
 How to clean Monaghan Aerochamber With Mask 6. Replace back piece when unit is completely dry and ready for use.


Cautions:

  • To ensure proper performance this product should only be cleaned according to these instructions
  • Do not leave the chamber unattended with children
  • Federal (USA) law restricts the sale of this device on or by the order of a physician

 

Instruction Guides for Monaghan Aerochamber Plus Valved Holding Chamber

 

FAQs About Monoghan Z STAT Aerochamber

Does the Aerochamber Plus Z STAT Chamber contain BPA?

None of the chambers are made or manufactured using BPA, natural rubber latex, phthalates, lead, or PVC. These chambers are manufactured in the US using parts from the US and Canada.

Is the Aerochamber Plus Z STAT Chamber Anti-static?

Yes, these chambers are manufactured using an anti-static polymer. Static will not build up (even if stored in a plastic bag) and they can be used straight from the package.

What if a patient has difficulties inhaling medication?

Designed to respond to shallow or low volume breathing patterns, the extra-sensitive inhalation valve on the Aerochamber Plus Z STAT makes it easier for patients to inhale the medication.

Customer Reviews

Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopnebulizer.com

Close