Drive Pediatric Fingertip Pulse Oximeter

Drive Pediatric Fingertip Pulse Oximeter

Brand/Manufacturer: DRIVE MEDICAL
Hpfy Stores Save
Authorized Retailer Badge
  • FSA Approved

Drive Pediatric Fingertip Pulse Oximeter is a portable non-invasive device intended for spot-checking of oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of pediatric patients in hospitals and hospital-type facilities. It is simple to operate and convenient to carry. When no or low signal is detected, the pulse oximeter will power off automatically in 8 seconds.

Features

  • Drive Pediatric Fingertip Pulse Oximeter features child-friendly design
  • 4-way OLED with six display modes
  • Adjustable brightness levels from 1 to 10
  • Prescription required
  • Portable, non-invasive spot check of oxygen saturation and pulse rate
  • Uses 2 AAA batteries
  • Comes in retail box
  • Lanyard, silicon case, and hang bag included
  • Low battery indicator
  • Note: Prescription required
  • Click Here For Manual

More Information

  • Precautions For Use:
    - Before use, carefully read the manual
    - Operation of the fingertip pulse oximeter may be affected by the use of an electrosurgical unit (ESU)
    - The fingertip pulse oximeter must be able to measure the pulse properly to obtain an accurate SpO2 measurement. Verify that nothing is hindering the pulse measurement before relying on the SpO2 measurement
    - Do not use the fingertip pulse oximeter in an MRI or CT environment
    - Do not use the fingertip pulse oximeter in situations where alarms are required. The device has no alarms. It is not for continuous monitoring
    - Do not use the fingertip pulse oximeter in an explosive atmosphere
    - The fingertip pulse oximeter is intended only as an adjunct in patient assessment. It must be used in conjunction with other methods of assessing clinical signs and symptoms
    - In order to ensure correct sensor alignment and skin integrity, the maximum application time at a single site for our device should be less than half an hour
    - Do not sterilize the device using autoclaving, ethylene oxide sterilizing, or immersing the device in liquid. The device is not intended for sterilization
    - Follow local ordinances and recycling instructions regarding disposal or recycling of the device and device components, including batteries
    - This equipment complies with IEC 60601-1-2:2007 for electromagnetic compatibility for medical electrical equipment and/or systems. However, because of the proliferation of radio-frequency transmitting equipment and other sources of electrical noise in healthcare and other environments, it is possible that high levels of such interference due to close proximity or strength of a source might disrupt the performance of this device
    - Portable and mobile RF communications equipment can affect medical electrical equipment
    - This equipment is not intended for use during patient transport outside the healthcare facility
    - This equipment should not be used adjacent to or stacked with other equipment
    - Do not disassemble, repair or modify the equipment without authority
    - These materials that contact with the patients skin contain medical silicone and ABS plastic enclosure are all pass the ISO10993-5 Tests for invitro cytotoxicity and ISO10993-10 Tests for irritation and delayed-type hypersensitivity
  • Rx only:
    Caution: Federal law (USA) restricts this device to sale by or on the order of a licensed practitioner.
  • It may be unsafe to:
    - Use accessories, detachable parts and materials not described in the instructions for use
    - Interconnect this equipment with other equipment not described in the instructions for use
    - Disassemble, repair or modify the equipment
  • Contraindication:
    - It is not for continuous monitoring
  • Maintenance and Storage:
    - Replace the batteries in a timely manner when low voltage lamp is lighted
    - Clean surface of the fingertip oximeter before it is used in diagnosis for patients
    - Remove the batteries if the oximeter is not operated for a long time
    - It is best to store the product in -20+55 and 93% humidity
    - Keep in a dry place. Extreme moisture may affect oximeter lifetime and may cause damage
    - Dispose of battery properly; follow any applicable local battery disposal laws
  • Cleaning the fingertip pulse oximeter:
    - Please use medical alcohol to clean the silicone touching the finger inside of Oximeter with a soft cloth dampened with 70% isopropyl alcohol.
    - Also clean the being tested finger using alcohol before and after each test
    - Do not pour or spray liquids onto the oximeter, and do not allow any liquid to enter any openings in the device
    - Allow the oximeter to dry thoroughly before reuse.

Specification

Particulars Specifications
Display Type OLED display
SpO2
Display range 0%~99%
Measurement range 70%~99%
Accuracy 70%~99%: ±3%; 0%~69% no definition
Resolution 1%
Pulse Rate
Display range 0bpm~254bpm
Measure range 30bpm~235bpm
Accuracy 30bpm~99bpm, ±2bpm; 100bpm~235bpm, ±2%
Resolution 1bpm
Probe LED Specifications
Red Wavelength 660±2nm
Red Radiant Power 1.8mW
IR Wavelength 940±10nm
IR Radiant Power 2.0mW
Power Requirements

Two AAA alkaline Batteries

Power consumption Less than 30mA
Battery Life Two AAA 1.5V, 600mAh alkaline batteries could be continuously operated as long as 30 hours

Environment Requirements

Operation Temperature 5°C ~ 40°C
Storage Temperature -20°C ~ +55°C
Ambient Humidity =80% no condensation in operation=93% no condensation in storage
Atmosphere pressure 86kPa ~ 106kPa

Warranty

2 year limited warranty