Atos Medical Provox XtraMoist HME

Atos Medical Provox XtraMoist HME

Brand/Manufacturer: ATOS MEDICAL
Hpfy Stores Save
Authorized Retailer Badge
  • FSA Approved

Atos Medical Provox XtraMoist HME makes the air more humid. Use it during the day, when you are taking it easy. It will help to breathe more comfortably and keep lungs healthier. If you have a voice prosthesis, simply press the HME to speak.

Benefits of Atos Medical Provox XtraMoist HME

  • Comfortable breathing
  • Reduces coughing and mucus production
  • Easy occlusion of the stoma for voicing.
  • Low-profile design

How to use Provox XtraMoist HME?

  • Insert the Provox XtraHME Cassette into the connector of the attachment device.
  • Breathe normally.
  • To speak, press the top lid of the Provox XtraHME Cassette down with a finger.
  • Note: Always release the lid completely at inhalation to avoid increased breathing resistance.
  • To remove the Provox XtraHME Cassette, hold the attachment device in place with two fingers and remove the HME Cassette from the holder.

Device lifetime and disposal

The HME is for single use and must be replaced at least every 24 hours, or more often if needed. Always follow medical practice and national requirements regarding biohazard when disposing of a used medical device.

Atos Medical Provox XtraMoist HME User Manual

What to buy with Provox XtraMoist?


Precautions to take while using Provox XtraMoist HME

  • Always test the function of the Provox XtraHME Cassette prior to use. The top lid should immediately return to its open position after releasing the finger.
  • Do not disassemble the Provox XtraHME Cassette since this will interfere with its proper function.
  • Do not reuse the Provox XtraHME Cassette or attempt to rinse it with water or any other substance. This will substantially reduce the function of the HME. Additionally the risk of potential infections may increase due to bacterial colonization of the foam.
  • Do not use the Provox XtraHME Cassette longer than 24 hours. The risk of potential infections may increase with the time of use due to bacterial colonization of the foam.
  • Do not administer medicated nebulizer treatment over the device since the medication can become deposited in the device.
  • Do not use humidifiers or heated humidified oxygen via a mask over the tracheostoma while using the device. The HME will become too wet. If oxygen therapy is required, use only non-heated humidified oxygen.

CONTRAINDICATIONS

The Provox XtraHME Cassette is not intended to be used by patients unable to remove or operate the device, unless the patient is under constant supervision of a clinician or a trained caregiver. For example, patients who are unable to move their arms, patients with decreased levels of consciousness, or patients with diseases that put them at risk for unpredictable periodic loss of consciousness. Do not use the Provox XtraHME Cassette in combination with cuffed tracheal cannula; breathing may be restricted and suffocation may occur. Do not use on patients with a low tidal volume, as the added dead space (5 ml) may cause CO 2 (carbon dioxide) retention at too low tidal volume.