DeVilbiss Vacu-Aide 7305 Series Homecare Suction Unit With Battery

DeVilbiss Vacu-Aide 7305 Series Homecare Suction Unit With Battery

Brand/Manufacturer: DEVILBISS
Hpfy Stores Save
Authorized Retailer Badge
  • Prescription required
  • Made in USA

DeVilbiss Vacu-Aide 7305 Series Homecare Suction Unit With Battery is a compact medical suctioning device which has been designed for reliable, portable operation. Because of the small size, lightweight, and DC operation, the DeVilbiss Suction Unit is ideal for providing suction in the home, in transport with an optional DC cord, or the unit can be operated anywhere with the rechargeable battery. Meets suction and capacity requirements in a small, lightweight design.

 

Item # Desc Pkg Price
7305P-D Suction Unit With Internal Filter Each
$460.89
$322.57
7305P-D-EXF Suction Unit With External Filter Each
$488.49
$341.92

Features

  • DeVilbiss Vacu-Aide 7305 Series Homecare Suction Unit With Battery includes:
    - Suction Unit
    - 800cc Disposable Container
    - Tubing
    - Elbow
    - AC and DC power cords
    - Carry case
    - Rechargeable battery
  • Vacuum adjustments allow for 80 to 550 mmHg and a free flow of 27 liters per minute
  • Adjustable flow regulator - Easy-to-turn knob conveniently placed directly below gauge, for easy use and control
  • Safety lock feature allows the knob to be twisted off
  • Easy-to-read gauge, especially important when precise measurements of vacuum are needed for the pediatric patient
  • Meets the RTCA/DO160D Aircraft Standard as well as the ISO-10079 1:1999 Suction Standard
  • Equipped with a switch mode power supply allowing operation on any AC voltage (100-240 VAC, 50/60 Hz)
  • Automatic float shut-off to prevent overflow into the unit
  • Uses a rechargeable battery with 60 minutes run time, automatically recharges when connected to the power supply
  • Unit can be operated while inside the carrying case
  • Battery for use up to one hour that provides the patient with added security when needed most
  • Indications:
    - More frequent or congested-sounding cough
    - Coarse rhonchi and expiratory wheezing audible to the patient and/or caregiver with or without auscultation
    - Visible secretions
    - Increased peak pressures during volume-cycled mechanical ventilation
    - Decreased tidal volumes during pressure-cycled ventilation
    - Indication by the patient that suctioning is necessary
    - Suspected aspiration of gastric or upper airway secretions
    - Otherwise unexplained increase in shortness of breath, respiratory rate, or heart rate
    - Decreases in vital capacity and/or oxygen saturation (as indicated by pulse oximetry), thought to be related to mucus plugging
  • User Manual
  • Click Here for AARC Guidelines
  • Also Available:
    -DeVilbiss Replacement Tubing for Suction Pump

Note: Prescription can be emailed or faxed to 1.203.616.2851. To email please: Click Here

More Information

  • Uses:
    - It is to be used to remove fluids from the airway or respiratory support system and infectious materials from wounds
    - The device creates a negative pressure (vacuum) that draws fluids through disposable tubing that is connected to a collection bottle
    - The fluids are trapped in the collection bottle for proper disposal
  • To reduce the risk of electrocution:
    - Do not use while bathing
    - Do not place or store product where it can fall or be pulled into a tub or sink
    - Do not place in or drop into water or other liquid
    - Do not reach for a product that has fallen into water
    - Unplug immediately
  • Caution:
    - This device is designed for the collection of non-flammable fluid materials in medical applications
    - Improper use during medical applications can cause injury or death
    - For all medical applications, all suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority
    - Some attachments or accessories may not fit the tubing supplied, hence all attachments or accessories should be checked prior to use to assure proper fit
  • How to operate the Suction Unit:
    - Before connecting the unit to the AC adapter or 12V DC cord, make sure that the power switch located on the side of the unit is in the position
    - Select power source desired
  • LED explanations:
    L1- Green
    - External power supplied to unit from AC power source or DC cord
    - Illuminated when external power is supplied
    L2 - Yellow
    - Battery is being charged
    - Light will go out when battery is fully charged
    L3 - Red
    - Low battery
    - Seek another power source and charge battery as soon as possible when light remains on continuous
  • AC operation:
    - Plug the small connector of the AC adapter into the DC power input located on the side of the unit
    - Plug the AC end into a grounded wall-outlet power source
  • 12V DC operation:
    - Plug the small connector of the DC power cord into the DC power input on the side of the unit
    - Plug the large connector into the 12V DC power receptacle of the automobile
  • Battery operation:
    - Verify that your unit has an internal rechargeable battery;
    - To ensure proper operation from internal battery, fully charge the battery for 10-17 hours as explained in the Battery Charging section
    - To operate the unit from an internal rechargeable battery, ensure that no external power sources are plugged into the DC power input on the side of the unit.
    - Once the power source is selected, simply turn the unit using the power switch located on the side of the unit
    - The power indicator light (displayed on the top of the unit) will indicate which power source is being used by staying continuously lit when external power is connected
  • Cleaning instructions:
    - Shut off unit using power switch and allow vacuum to drop
    - Disconnect power source from the DC input receptacle on the unit
    - With the collection bottle still in the holder, remove the lid
    - The bottle can now be taken out of the holder to be emptied Collection bottles and lids should be thoroughly cleaned after each use by one of the following methods:
    All Bottles:
    - Wash in a hot water/dishwashing detergent solution and rinse with clean, hot tap water - Then wash in one part vinegar to three parts hot water solution
    - Rinse with hot tap water and air dry
    1,200ml Reusable Bottle only:
    - Wash in a hot water/dishwashing detergent solution and rinse with clean, hot tap water - Then wash with rubbing alcohol and air dry
    - Wash in a hot water/dishwashing detergent solution and rinse with clean, hot tap water - Then wash with a commercial (bacterial-germicidal) disinfectant, follow disinfectant manufacturer;s recommended instructions and dilution rates carefully
    - Clean the 1200 ml autoclavable jar, lid assembly, gasket, seal washer, float guide, and float thoroughly with mild soap
    - Rinse thoroughly with clean water and dry thoroughly
    - Place parts in autoclave as follows ensuring the parts are not touching
    - Jar with open end down

Specification

Particulars

Dimensions

7305D Series

3.8lb (1.7kg)

7305P Series

6.3lb (2.9kg)

Electrical Requirements

100 to 240 V AC 50/60 Hz .75 A max; 12 V DC, 33 W max

7305P Series Internal Rechargeable Battery

Factory Equipped

Vacuum Range

80 to 550 mmHg

Air Flow @ pump inlet

27 LPM (free flow) typical (may be less when running from internal battery)

Collection Bottle Capacity

800 ml (cc) Disposable

Warranty

2 year limited warranty on unit